Descrizione
In the Matter door lock applications of the Nordic Semiconductor nRF Door Lock and Access Control Add-on v1.0.0 through v1.1.1, AccessManager::ValidateCredential() checks only credential occupancy and the secret bytes, and never reads the owning user's UserStatus. It also returns success when no owning user can be resolved. A user suspended by setting their status to OccupiedDisabled can continue to unlock the door with their previously assigned credential, and an orphaned but occupied credential is also accepted. Fixed in v1.2.0.
Come correggere
Priorità: Media — correggere nel prossimo ciclo di patch. Motivazione: CVSS 7.0, EPSS 0.2% (percentile 10).
Versioni da aggiornare
- Nordic Semiconductor ASA nRF Door Lock and Access Control Add-on: vulnerabile la versione
v1.0.0 through v1.1.1 (inclusive). Fixed in v1.2.0.→ installare l'ultima release supportata dal vendor.
Mitigazioni temporanee
Da applicare solo se non è possibile aggiornare subito:
- Restringere l'accesso al componente, applicare il principio del minimo privilegio e controllare i log per operazioni non autorizzate.
Verifica
- Individuare tutti gli asset con il prodotto interessato (inventario, scanner di vulnerabilità, CMDB).
- Confrontare la versione installata con quelle indicate sopra.
- Applicare l'aggiornamento in un ambiente di test, poi in produzione; riavviare i servizi se richiesto.
- Ripetere la scansione per confermare la correzione.
Configurazioni interessate
| Vendor | Prodotto | Versioni vulnerabili | Corretta in |
|---|---|---|---|
| Nordic Semiconductor ASA | nRF Door Lock and Access Control Add-on | v1.0.0 through v1.1.1 (inclusive). Fixed in v1.2.0. | — |